Specializing in R&D & Production in xPON & Optical Communication & CATV & Ethernet Networking
HANGZHOU DAYTAI NETWORK TECHNOLOGIES CO.,LTD.
DAYTAI-HANGZHOU-CHINA
Tel:
+86-571-8735 7725-Español
+86-571-8735 7726-English
+86-571-8735 7727-English
+86-571-8735 7728-English
Fax : +86-571-8735 7798
Mr.Amani
Skype:daytai-amani
Mobile:+86-137 7755 3827
WeChat:+86-180 7288 6827
E-mail:info@daytai.com
Web Site:WWW.DAYTAI.COM
96Channel 50G AWG DWDM,(DT-DWDM-96CH50G-AWG),Channel Spacing (GHz):50G,Single Fiber OR Dual Fiber is Optional,
Number of Channels:96CH(Max),Low Insertion Loss,Maximum Input Optical Power:500 mW,which can be used in general DWDM
96Channel 50G AWG DWDM,(DT-DWDM-96CH50G-AWG),Channel Spacing (GHz):50G,Single Fiber OR Dual Fiber is Optional,
Number of Channels:96CH(Max),Low Insertion Loss,Maximum Input Optical Power:500 mW,which can be used in general DWDM
systems. Based on the athermal design and packing, it is totally passive product which does not require any electrical power
or temperature control,Customized wavelengths,Connector:Without,SC/APC,SC/UPC,FC/APC,FC/UPC,LC/APC,LC/UPC,ST OR Specify.
★Features
⊙Wide pass band
⊙Low Insertion Loss
⊙High Channel Isolation
⊙High Stability and reliability
★Applications
⊙WDM Network
⊙Access Network
⊙Telecommunication
Item | Conditions | Specification | /Unit | ||
Min | Typ | Max | |||
Number of Channels | 96 | CH | |||
Number Channel Spacing | 50 | GHz | |||
Center Wavelength | ITU frequency, measured in vacuum. | C-band | nm | ||
Clear Channel Passband | Centered at each ITU channel frequency | ± 6.25 | GHz | ||
Wavelength Stability | Maximum range of the wavelength error of all channels and temperatures in average polarization. | ±0.05 | nm | ||
-1dB Channel Bandwidth | Clear channel bandwidth defined by passband shape. For each Channel. | 0.20 | nm | ||
-3dB Channel Bandwidth | Clear channel bandwidth defined by passband shape. For each channel. | 0.28 | nm | ||
Optical Insertion Loss at ITU grid | Defined as the minimum transmission at ITU wavelength for all channels. For each channel, at all temperatures and polarizations with connectors. | 7.5 | dB | ||
Adjacent Channel Isolation | Ratio of peak transmission to the maximum transmission over both adjacent ITU wavelengths | 25 | dB | ||
Non-Adjacent,Channel Isolation | Ratio of peak transmission in channel passband to the maximum transmission over all non-adjacent ITU wavelength | 30 | dB | ||
Total Crosstalk | Ratio of power in channel to power in all other ITU wavelength | 20 | dB | ||
Insertion Loss Uniformity | The difference between the maximum and minimum of passband across all channels | 0.8 | 1.3 | dB | |
Directivity(Mux Only) | Ratio of reflected power out of any channel(other than channel n)to power in from the input channel n | 45 | dB | ||
Optical Return loss | Input & output ports | 40 | dB | ||
Polarization Dependent Loss in Clear Channel Band | Worst-case value measured in ± 20GHz around ITU wavelength for each port. | 0.3 | 0.5 | dB | |
Polarization Mode Dispersion | Maximum differential group delay within reference ITU wavelength | 1.0 | ps | ||
Chromatic Dispersion | Maximum change rate of group delay versus wavelength within reference ITU wavelength | -20 | +20 | ps/nm | |
Maximum Input Optical Power | Maximum continuous optical power | 500 | mW | ||
Operating Temperature | Device Not Powered on Heater Element | -5 | 65 | oC | |
Operating Humidity | Non-Condensing Environment | 5 | 85 | %RH | |
Storage Temperature | Device Not Powered on Heater Element | -40 | 85 | oC | |
Storage Humidity | Non-Condensing Environment | 0 | 95 | %RH |
★Ordering Information
XAWG | X | XX | X | XXX | X | X | X | XX |
Type | Band | Number of Channels | Spacing | 1st Channel | Chip Type | Package | Fiber Length (Total Length) | In/Out Connector |
AAWG= Athermal AWG | C=C-Band L=L-Band D=C+L-Band X=Customize | 16=16-CH 32=32-CH 40=40-CH 48=48-CH 96=96-CH XX=Special | 1=100G 2=200G 5=50G X=Special | C62=C62 H61=H61 C60=C60 H59=H59 . XXX=special | G=Gaussian F=Flat Top | M=Module R=Rack X=Special | 1=0.5m 2=1m 3=1.5m 4=2m X=Specify | 0=None 1=FC/APC 2=FC/PC 3=SC/APC 4=SC/PC 5=LC/APC 6=LC/PC 7=ST/UPC X=Specify |