Grade C 2000 Series Smart PDU
Grade C 2000 Series Smart PDU
Grade C 2000 Series Smart PDU
Grade C 2000 Series Smart PDU
Grade C 2000 Series Smart PDU
Grade C 2000 Series Smart PDU
Grade C 2000 Series Smart PDU
Grade C 2000 Series Smart PDU

Standard Size Smart Power Distribution Unit ( Smart PDU),Grade:C 

DAYTAI 2000 Series  Smart PDU (DT-SPDU-2000C),(Master 

Monitoring+Outlet Monitoring)


Model: DT-SPDU-2000C Brand: DAYTAI
Inquire
Product Description

Standard Size Smart Power Distribution Unit ( Smart PDU),Grade:C DAYTAI 2000 Series  Smart PDU (DT-SPDU-2000C),

(Master Monitoring+Outlet Monitoring),PDU input Power Plug:European OR American...is optional,PDU Output Socket 

Module:IEC / US / Australia / France / Italy / Germany...is Optional.


■Smart PDU Basic Introduction

⊙Smart Power Distribution Unit( Smart PDU) is the world-advanced new generation network power distribution and monitoring device 。

Through LAN or WAN,the manager can   monitor 、control and manage the power of many equipment in the cabinet of the data   room located all over the world.

 

■Smart PDU Product Application

⊙DAYTAI Grade C Smart PDU is widely used in 19-inch standard and non-standard server cabinets or networks.


■Features

⊙Remote monitor

⊙Total load current(A)

⊙Working  Voltage(V)

⊙Total Power(KW)

⊙electric energy(KWH) .Frequency

⊙load Current of each outlet(A)

.On/Off state of each outlet

⊙Temperature/Humidity State

⊙Smog state

⊙Water-logging

⊙Door State

Specification



Main Function

Technical instruction

Product classification

Monitor

Control

A

B

C

D

 

 

 

 

 

Monitoring

Total load current

●

●

●

●

Load current of each outlet

●

●

●


On/Off state of each outlet

●

●



Total Power

●

●



Total Energy

●

●

●

●

Work Voltage

●

●

●

●

Frequency

●

●

●

●

Temperature/Humidity

●

●

●

●

Smog sensor

●

●

●

●

Door sensor

●

●

●

●

Water logging sensor

●

●

●

●

 

Controlling

On/Off of the Power


●



On/Off of each outlet

●




Set the interval time of outlets' sequential on/off

●




Set the on/off time of each outlet

●




 

Set the limiting value to alarm

The limiting range of total load current

●

●

●

●

The limiting range of the load current of each outlet

●


●


The limiting range of the work voltage

●

●

●

●

The limiting range of temperature and humidity

●

●

●

●

 

 

System automatic alarm

The total load current exceeds the limiting value

●

●

●

●

The load current of individual outlet exceeds the limiting value

●

●

●

●

Temperature/Humidity exceeds the limiting value

●

●

●

●

Smog

●

●

●

●

Water-logging

●

●

●

●

Door opening

●

●

●

●

Alarming method

The buzzer alarms

●

●

●

●

Automatically send E-mail to system administrator

●

●

●

●

Automatically send E-mail to system administrator

●

●

●

●

User management

Set user's right,support software update

●

●

●

●


■DAYTAI Smart PDU Function Category

Item

Function Category

Function Description

1

Master Monitoring

 (总监)

Monitors only PDU total input loop: total voltage, current, power and energy. Only unit-level data is accessible; no individual outlet data or switching functions.

2

Outlet Monitoring

(分监)

Each output socket independently samples current, power and energy. Per-device power consumption viewable, with branch overload alarm. Data-collection only; switching function may be absent.

3

Master Switching

(总控)

Built-in main relay: all sockets switch on/off collectively, no per-channel control. Turning off main control cuts power to all connected devices.

4

Outlet Switching

(分控)

Each outlet equipped with independent relay: supports individual on/off, remote reboot and power-on sequencing. Port power failure does not impact other outlets.


■Order Information For Smart PDU

DAYTAI 2000 Series (Standard Size) Smart PDU

Series

DAYTAI Model

Grade

Function

PDU input

 Power Plug

PDU Socket Module

2000 Series

 (Standard Size) 

 

DT-SPDU-2000A

Grade:A

Master Monitoring + Outlet Monitoring + Outlet Switching

European OR American...is Optional.

IEC/US/Australia/France/Italy/Germany...Socket Module is Optional.

DT-SPDU-2000B

Grade:B

Master Monitoring + Outlet Monitoring + Master Switching

DT-SPDU-2000C

Grade:C

Master Monitoring + Outlet Monitoring

DT-SPDU-2000D

Grade:D

Master Monitoring

DAYTAI 5000 Series (Nonstandard Size / Custom sizes available)

Series

DAYTAI Model

Grade

Function

PDU input

 Power Plug

PDU Socket Module

5000 Series

(Nonstandard Size /

Custom sizes available)

DT-SPDU-5000A

Grade:A

Master Monitoring + Outlet Monitoring + Outlet Switching

European OR American...is Optional.

IEC/US/Australia/France/Italy/Germany...Socket Module is Optional.

DT-SPDU-5000B

Grade:B

Master Monitoring + Outlet Monitoring + Master Switching

DT-SPDU-5000C

Grade:C

Master Monitoring + Outlet Monitoring

DT-SPDU-5000D

Grade:D

Master Monitoring