Horizontal Closure,DT-FOSC-H8018,Protection Grade:IP68,Number of
ports:6 Pieces:3 inlet+3 outlet ,Diameter of fiber optic cable:Φ8—
Φ16MM,Max.Capacity:Bunchy:96Cores.12 Core or 24 Core Splice
Tray is Optional,(xCore=x*12Core Splice Tray,xCore=x*24Core Splice
Tray),Outside Dimension(LxWxH): 413×160×88MM.Weight:2.75-3.20Kg.
Horizontal Closure,DT-FOSC-H8018,Protection Grade:IP68,Number of ports:6 Pieces:3 inlet+3 outlet ,Diameter of fiber optic cable:Φ8—
Φ16MM,Max.Capacity:Bunchy:96Cores.12 Core or 24 Core Splice Tray is Optional,(xCore=x*12Core Splice Tray,xCore=x*24Core Splice
Tray),Outside Dimension(LxWxH): 413×160×88MM.Weight:2.75-3.20Kg.
★Scope of application
⊙This Installation Manual is suit for the Fiber Optic Splice Closure (Hereafter abbreviated as FOSC), as the guidance of proper installation.
⊙The scope of application is:aerial,underground,wall-mounting,duct-mounting, handhole-mounting. The ambient temperature ranges
from -20℃ to +65℃.
Ietm | |
Outside dimension (LxWxH) | 413×160×88 (mm) |
Weight (excluding outside box) | 1580g-2100g |
Number of inlet/outlet ports | 3 (pieces) on each side (total 6 pieces) |
Diameter of fiber cable | Φ8—Φ16 (mm) |
Capacity of FOSC | Bunchy: 12—96(Cores) Ribbon: max. 144(Cores) |
★Main components
No. | Name of components | Quantity | Usage | Remarks | |
1 | Housing | 1 set | Protecting fiber cable splices in whole | Internal diameter: 270×100×60 (mm) | |
2 | Fiber optic splice tray (FOST) | max. 2 pcs (bunchy) max.2 pcs (ribbon) | Fixing heat shrinkable protective sleeve and holding fibers | Suitable for: Bunchy:12,24(cores) Ribbon:3 (pieces) | |
3 | Foundation | 1 set | Fixing reinforced core of fiber- cable and FOST | ||
4 | Seal fitting | 1 set | Sealing between FOSC cover and FOSC bottom | ||
5 | Port plug | 4 pieces | Sealing empty ports | ||
6 | Earthing deriving device | 1 set | Deriving metallic components of fiber cable in FOSC for earthing connection | Configuration as per requirement |
★ Main accessories and special tools
No. | Name of accessories | Quantity | Usage | Remarks |
1 | Heat shrinkable protective sleeve | Protecting fiber splices | Configuration as per capacity | |
2 | Nylon tie | Fixing fiber with protective coat | Configuration as per capacity | |
3 | Insulation tape | 1 roll | Enlarging diameter of fiber cable for easy fixing | |
4 | Seal tape | 1 roll | Enlarging diameter of fiber cable which fits in with seal fitting | Configuration as per specification |
5 | Hanging hook | 1 set | For aerial use | |
6 | Earthing wire | 1 piece | Putting through between earthing devices | |
7 | Abrasive cloth | 1 piece | Scratching fiber cable | |
8 | Labeling paper | 1 piece | Labeling fiber | |
9 | M6 Special wrench | 1 pieces | Fixing small bolts of housing | |
10 | M10 Special wrench
| 1 piece | Tightening nut of reinforced core |
★Fiber Optic Splice Closures (FOSC) inspecting and testing items
Inspecting item | Technical Requirements | Inspecting type | |
Routine test (Before leaving factory) | Type test | ||
Package | Each small package contains one fiber optic splice closure, together with its accessories, tools, installation manual and packing list. | full | At least 3 sets sampled each time |
Appearance | Intact in shape, no burrs, bubbles, chaps, pores, warps, impurities and other defects, all background colors should be even and continual. | ||
Sign | There is a clear sign on the housing, such as name and model of the product, etc. | ||
Fiber storage device | The fibers reserved are to be winded in fiber optic splice tray (FOST), the length of fibers housed in FOST is ≥1.6m, the curved radius is >30mm. During the installation and maintenance, there should be no attenuation on fibers. | At least 3 sets sampled each time | |
Electrical jointing device | Inside FOSC: metallic components of fiber cables has the functions of electrical putting through, earthing connection and disconnecting. It is possible to install earthing deriving device outside the housing | ||
Sealing performance | After sealing according to the stipulated operation procedures, the injected air pressure is 100KPa±5Kpa, when immersed in clean water of normal temperature for 15 minutes, there should be no air bubbles, then observed for 24 hours, there should be no change of air pressure. | ||
Re-sealing performance | After reopening and resealing according to the stipulated operation procedures, the injected air pressure is 100KPa±5Kpa, when immersed in clean water of normal temperature for 15 minutes, there should be no air bubbles, then observed for 24 hours, there should be no change of air pressure. | ||
Pull | Bearing pull is ≧ 800N at axle orientation, there should be no breakage on the housing. | ||
Punching | Bearing pressure of 2000N/250px for 1 minutes, there should be no breakage on the housing | ||
Impact | Bearing impact energy of 16N•m, 3 times of impacts there should be not breakage on the housing | ||
Bending | The spot between the FOSC and seal fitting can bear bending tension of 150N at bending angle of ±450 for 10 circles, there should be no breakage on the housing | At least 3 sets sampled each time | At least 3 sets sampled each time |
Torsion | Bearing torsion 50N•m, 10 circle at torsion angle±900, There should be no breakage on the housing. | ||
Temperature circle | Injected air pressure of 60KPa±5 KPa, the temperature circle ranging from -40℃~+65℃, 10 times of the circular tests (one circular consists of high temperature for 2 hours + indoor temperature for 2 hours + low temperature for 2 hours + indoor temperature for 2 hours ) when the pressure declines, the amplitude is ≦5Kpa, immerse the swatch in clean water of normal temperature for 15 minutes, there should be no air bubbles. | ||
Voltage resistance strength | After sealing the FOSC according to the stipulated operation procedures, immerse it in clean water of normal temperature in 1.5m depth for 24 hours, there should be no breakdown or arc over between the metallic components of the FOSC, between metallic components and the ground at DC 15KV for 1 minutes. | ||
Isolating resistance | After sealing the FOSC according to stipulated operation procedure, immerse it in clean water in 1.5m depth for 24h, the isolating resistance between the metallic components of the FOSC, between the metallic components and the ground should be ≧ 2×104MΩ. |