Product Performance(Gaussian Athermal AWG)                                 
 

Parameters

 
 

Condition

 
 

Specs

 
 

Units

 
 

Min

 
 

Typ

 
 

Max

 
 

Number of Channels

 
 

 

 
 

41

 
 

 

 
 

Number Channel Spacing

 
 

100GHz

 
 

100

 
 

GHz

 
 

Cha. Center Wavelength

 
 

ITU frequency.

 
 

C -band

 
 

nm

 
 

Clear Channel Passband

 
 

 

 
 

±12.5

 
 

GHz

 
 

Wavelength Stability

 
 

Maximum range of the wavelength error  of all  channels and temperatures in average polarization.

 
 

±0.05

 
 

nm

 
 

-1 dB Channel Bandwidth

 
 

Clear channel bandwidth defined by passband shape. For each channel

 
 

0.24

 
 

 

 
 

 

 
 

nm

 
 

-3 dB Channel Bandwidth

 
 

Clear channel bandwidth defined by passband shape. For each channel

 
 

0.43

 
 

 

 
 

 

 
 

nm

 
 

Optical Insertion Loss at ITU grid

 
 

Defined as the minimum transmission at ITU wavelength for all channels.  For each channel, at all temperatures and polarizations.

 
 

 

 
 

4.5

 
 

6.0

 
 

dB

 
 

Adjacent Channel Isolation

 
 

Insertion loss difference from the mean transmission at the ITU grid  wavelength to the highest power, all polarizations, within the ITU band of  the adjacent channels.

 
 

25

 
 

 

 
 

 

 
 

dB

 
 

Non-Adjacent, Channel Isolation

 
 

Insertion loss difference from the mean transmission at the ITU grid  wavelength to the highest power, all polarizations, within the ITU band of  the nonadjacent channels.

 
 

29

 
 

 

 
 

 

 
 

dB

 
 

Total Channel Isolation

 
 

Total cumulative insertion loss difference from the mean transmission at  the ITU grid wavelength to the highest power, all polarizations, within the  ITU band of all other channels, including adjacent channels.

 
 

22

 
 

 

 
 

 

 
 

dB

 
 

Insertion Loss Uniformity

 
 

Maximum range of the insertion loss variation within ITU across all  channels, polarizations and temperatures.

 
 

 

 
 

 

 
 

1.5

 
 

dB

 
 

Directivity(Mux Only)

 
 

Ratio of reflected power out of any channel(other than channel n)to  power in from the input channel n

 
 

40

 
 

 

 
 

 

 
 

dB

 
 

Insertion Loss Ripple

 
 

Any maxima and any minima of optical loss across ITU band, excluding  boundary points, for each channel at each port

 
 

 

 
 

 

 
 

1.2

 
 

dB

 
 

Optical Return loss

 
 

Input & output ports

 
 

40

 
 

 

 
 

 

 
 

dB

 
 

PDL/Polarization Dependent Loss in Clear Channel Band

 
 

Worst-case value measured in ITU band

 
 

 

 
 

0.3

 
 

0.5

 
 

dB

 
 

Polarization Mode Dispersion

 
 

 

 
 

 

 
 

 

 
 

0.5

 
 

ps

 
 

Maximum Optical Power

 
 

 

 
 

 

 
 

 

 
 

23

 
 

dBm

 
 

MUX/DEMUX input/ output

 

Monitoring range

 
 

 

 
 

-35

 
 

 

 
 

+23

 
 

dBm

 

IL Represents the worst case over a +/-0.01nm windowaround the ITU wavelength;

PDL was measured on average polarization over a +/-0.01nm window around the ITU wavelength.


Ordering Information 

 

AWG

 

 

 
 

X

 
 

XX

 
 

X

 
 

XXX

 
 

X

 
 

X

 
 

X

 
 

XX

 
 

Band

 
 

Number of Channels

 
 

Spacing

 
 

1st Channel

 
 

Filter Shape

 
 

Package

 
 

Fiber Length

 
 

In/Out Connector

 
 

C-Band

 

L-Band

 

C+L-Band

 

Special

 
 

16-CH

 

32-CH

 

40-CH

 

48-CH

 

Special

 
 

100G

 

200G

 

50G

 

Special

 
 

C60

 

H59

 

C59

 

H58

 

special

 
 

Gaussian

 

Broad Gaussiar

 

Flat Top

 
 

Module

 

Rack

 

Special

 
 

0.5m

 

1m

 

1.5m

 

2m

 

2.5m

 

3m

Specify 
 

None

 

FC/APC

 

FC/PC

 

SC/APC

 

SC/PC

 

LC/APC

 

LC/PC

 

ST/UPC

 

Specify

 

                             THE END